Welcome! This detailed guide provides essential information for utilizing the Alice NightOne system effectively and safely during your home sleep study․

Carefully review all instructions and safety precautions within this manual before commencing the recording process, ensuring optimal data collection․

The Alice NightOne system represents a convenient and accurate method for conducting a sleep study in the comfort of your own home․ This system is designed to monitor key physiological parameters during sleep, providing valuable data for the diagnosis of sleep disorders․

This user manual serves as a comprehensive resource, guiding you through each step of the process – from setting up the device and applying the sensors, to understanding the device indicators and initiating the recording․

The Alice NightOne aims to evaluate your breathing patterns while you sleep, utilizing an effort belt, SpO2 sensor, and nasal cannula․ Remember to follow the provided instructions diligently, and prioritize safety throughout the study․ A successful home sleep test relies on proper application and adherence to the guidelines outlined within this document․

Preparation is key; begin approximately 30 minutes before bedtime․

What is the Alice NightOne?

The Alice NightOne is a simplified, single-use home sleep apnea testing (HSAT) device․ It’s a compact, portable system designed to record your breathing patterns and oxygen levels during sleep, assisting in the detection of sleep apnea․ Unlike traditional polysomnography performed in a lab, the Alice NightOne allows for testing within your familiar sleep environment․

The device itself, paired with a disposable nasal cannula, effort belt, and SpO2 sensor, captures essential data․ This data is then analyzed by qualified professionals to determine if you experience any breathing disturbances during sleep․

This system is intended for a single patient use and is provided with a user manual and quick start guide․ Following the instructions carefully is crucial for accurate results․ The purpose is to evaluate your breathing while sleeping, offering a convenient diagnostic pathway․

Package Contents

Your Alice NightOne package is carefully assembled to ensure a smooth and successful home sleep study experience․ Upon opening, you should find the following components:

  • Alice NightOne Device: This is the central recording unit, featuring an attached effort belt and SpO2 sensor․
  • Nasal Cannula: A disposable tube used to deliver a gentle flow of air and monitor nasal airflow․
  • User Manual: A comprehensive guide containing detailed instructions, safety information, and troubleshooting tips․
  • Quick Start Guide: A condensed version of the manual, providing a rapid overview of the setup process․

Please verify that all listed items are present before proceeding․ If any components are missing or damaged, contact your healthcare provider immediately․ Proper utilization of these components, as detailed in this manual, is vital for accurate results․

Device Components

The Alice NightOne device itself is a compact, user-friendly unit designed for comfortable overnight use․ Key components include the main recording module, which houses the data storage and processing capabilities․ Integrated with the device is the effort belt, crucial for measuring respiratory effort during sleep․

Additionally, a SpO2 sensor is pre-attached, continuously monitoring blood oxygen saturation levels․ The device features a cannula port for easy connection of the nasal cannula․ Various indicator lights display device status and recording progress․ Familiarize yourself with these components and their functions, as outlined in this manual, to ensure proper setup and operation․

Understanding these parts is essential for a successful sleep study․

Included Accessories

Your Alice NightOne package includes several essential accessories to facilitate a successful home sleep study․ You will find a nasal cannula, designed for comfortable oxygen delivery during sleep․ A user manual and a quick start guide are provided for easy reference and setup assistance․

The package also contains the Alice NightOne device itself, pre-equipped with an attached effort belt and SpO2 sensor․ These components work together to gather crucial data throughout the night․ Ensure all listed items are present before beginning the study․ Proper utilization of these accessories, as detailed in this guide, is vital for accurate results and a comfortable experience․

Carefully inspect all items upon opening the package․

Setting Up the Alice NightOne Device

Preparing the Alice NightOne for your sleep study involves connecting a few key components․ Begin by carefully connecting the effort belt, which measures your breathing effort during sleep․ Next, securely attach the SpO2 sensor; this monitors your blood oxygen levels throughout the night․

Finally, connect the nasal cannula to the top of the device․ Ensure all connections are firm but gentle to avoid damage․ The cannula icon will begin flashing amber, indicating it’s ready for use․ Following these steps correctly is crucial for accurate data collection․ Refer to the illustrations in the user manual for visual guidance during this setup process․

Double-check all connections before proceeding․

Connecting the Effort Belt

The effort belt is a vital component, measuring your breathing effort during sleep․ One side of the belt typically comes pre-assembled into the Alice NightOne device itself․ Carefully unroll the remaining portion of the belt, ensuring it isn’t twisted․

Wrap the belt snugly around your chest, positioning it just below your breasts (for women) or pectoral muscles (for men)․ The belt should be secure enough to stay in place during movement but not so tight as to restrict breathing․ Secure the belt using the provided fasteners, ensuring a comfortable fit․ Proper placement is essential for accurate respiratory effort readings․ Consult the manual’s diagrams for correct positioning․

A secure, comfortable fit is paramount․

Attaching the SpO2 Sensor

The SpO2 sensor, often referred to as a finger probe or oximeter, measures the oxygen saturation in your blood․ It’s crucial for assessing your overall respiratory health during the sleep study․ Before attaching, ensure your hands are warm and dry for optimal readings․

Gently place the sensor on the index finger of your non-dominant hand․ The sensor should fit snugly, but not too tightly, allowing for proper blood flow․ Avoid using nail polish or artificial nails, as these can interfere with the sensor’s accuracy․

Connect the sensor cable securely to the designated port on the Alice NightOne device․ The manual provides a visual guide for correct connection․ Ensure a stable connection throughout the night․

Connecting the Nasal Cannula

The nasal cannula delivers a gentle flow of air to help maintain open airways during your sleep study․ Begin by carefully removing the cannula from its packaging, ensuring it’s free from any kinks or damage․ Locate the port on the top of the Alice NightOne device specifically designed for the cannula connection․

Screw the cannula securely into the device port until you feel a firm connection․ The cannula icon on the device will begin flashing amber, indicating it’s ready for use․ Avoid forcing the connection; gentle pressure is sufficient․

Proper connection is vital for accurate data collection․ Refer to the user manual for a detailed illustration of the connection process․

Applying the Alice NightOne

Proper application of the Alice NightOne is crucial for a successful sleep study․ Begin by ensuring the effort belt is correctly connected and adjusted to your chest size․ Next, carefully position the nasal cannula, looping it comfortably around your ears and securely under your chin․

The cannula should rest gently in your nostrils without causing discomfort or restricting breathing․ Simultaneously, place the SpO2 sensor on your non-dominant finger, ensuring a snug but not overly tight fit․

Double-check all connections and positioning before initiating the recording․ Refer to the user manual for detailed diagrams and troubleshooting tips to guarantee accurate data collection throughout the night․

Securing the Chest Belt

The chest belt, or effort belt, is a vital component of the Alice NightOne system, measuring your breathing effort during sleep․ One side of the belt typically comes pre-assembled to the Alice NightOne device itself, simplifying the initial setup․ Ensure the belt is positioned horizontally around your chest, just below your pectoral muscles․

Adjust the strap to achieve a snug, yet comfortable fit – it shouldn’t be too tight, restricting breathing, nor too loose, allowing for movement and inaccurate readings․ Fasten the belt securely, verifying it remains in place throughout the night․

Properly securing the chest belt is essential for obtaining reliable respiratory effort data during your home sleep study, as outlined in the user manual․

Positioning the Nasal Cannula

The nasal cannula delivers a gentle flow of air to help maintain open airways during your sleep study with the Alice NightOne․ After screwing the cannula into the top of the device, carefully loop it around your ears and gently under your chin․

Ensure the prongs of the cannula are comfortably inserted into your nostrils – they should not cause discomfort or irritation․ The goal is a secure, yet non-restrictive fit․

Avoid kinking or bending the cannula tubing, as this can affect airflow․ Refer to the user manual for visual guidance․ Proper positioning is crucial for accurate data collection and a comfortable sleep experience throughout the night․

Placing the SpO2 Sensor

The SpO2 sensor, included with your Alice NightOne, measures your blood oxygen saturation levels during sleep․ It’s vital to apply this sensor to your non-dominant hand, typically the index finger, for optimal readings․

Ensure your finger is clean and dry before attaching the sensor․ Gently slide the sensor onto your fingertip, ensuring a snug but comfortable fit․ Avoid excessive pressure, as this can interfere with circulation and accuracy․

Refer to the user manual for illustrative diagrams․ Proper placement is essential for reliable data․ If the sensor feels uncomfortable or falls off during the night, reposition it carefully, consulting the guide if needed․

Understanding Device Indicators

The Alice NightOne device utilizes several icons to communicate its operational status throughout your sleep study․ Familiarizing yourself with these indicators is crucial for ensuring a successful recording․ The device displays icons representing power, recording status, and sensor connectivity․

These visual cues provide real-time feedback on the device’s performance․ The user manual contains a comprehensive list of all possible icons and their corresponding meanings․ Pay close attention to the cannula icon, as its flashing amber state indicates readiness for cannula attachment․

Understanding these indicators allows you to quickly identify and address any potential issues during the study, ensuring accurate data collection․

Icon Meanings

The Alice NightOne employs a series of icons to clearly convey device status․ A solid power icon signifies the device is on and functioning correctly․ A flashing record icon indicates the study is actively recording data․ Conversely, a paused record icon shows the recording is temporarily halted․

Crucially, the cannula icon’s behavior is informative; a flashing amber light signals the device is prepared to accept the nasal cannula connection․ A solid cannula icon confirms a secure connection․ Sensor connectivity is also visually represented – a lit sensor icon means the sensor is properly attached and transmitting data․

Refer to the complete icon glossary within this user manual for detailed explanations of each symbol and potential troubleshooting steps․

Flashing Amber Cannula Indicator

A flashing amber cannula indicator on the Alice NightOne device is a critical signal during setup․ This indicates the device is actively awaiting the connection of the nasal cannula․ It’s a preparatory state, confirming the system is ready to establish airflow monitoring․

Do not attempt to initiate the sleep study before this amber light is flashing; Ensure the device is powered on and functioning correctly․ Once the amber light is observed, carefully screw the nasal cannula firmly into the designated port on top of the Alice NightOne unit․

A solid cannula icon will then appear, confirming a secure connection․ Refer to the user manual if the light doesn’t change after connecting the cannula․

Starting and Stopping the Recording

Initiating the Sleep Study: After ensuring all components – effort belt, SpO2 sensor, and nasal cannula – are correctly connected and the cannula icon displays a solid color, the Alice NightOne is ready to begin recording․ The device automatically starts recording once it detects proper sensor connections and stable operation․

Device Operation During Sleep: The Alice NightOne is designed for quiet and unobtrusive operation throughout the night․ Avoid pressing any buttons during the recording, as this could disrupt the data collection process․

To stop the recording in the morning, simply disconnect the nasal cannula from the device․ The Alice NightOne will automatically cease recording upon disconnection․ Ensure the device is returned with all accessories as instructed․

Initiating the Sleep Study

Before beginning, confirm the Alice NightOne device is powered on and displaying a stable indicator light․ Verify all sensors – the effort belt, SpO2 sensor, and nasal cannula – are securely connected to both your body and the device itself․ Pay close attention to the cannula; it should be firmly screwed into the top of the device․

The system is designed to automatically initiate recording once it detects proper sensor functionality․ You will observe a change in the cannula icon, typically transitioning from a flashing amber state to a solid color, indicating readiness․

Avoid manually starting the device; it’s self-activating․ Ensure you’ve allowed approximately 30 minutes for the device to acclimate before retiring for the night․

Device Operation During Sleep

During your sleep study, the Alice NightOne is designed for silent and unobtrusive operation․ You should not experience any discomfort or disturbance from the device itself․ It continuously monitors your breathing patterns, oxygen saturation levels, and effort throughout the night, automatically recording the data․

Avoid intentionally manipulating the device or disconnecting any sensors while sleeping․ Minor adjustments to the nasal cannula for comfort are permissible, but ensure it remains securely positioned․

The device operates independently, requiring no active participation from you․ Simply sleep as you normally would, and the Alice NightOne will diligently collect the necessary information for your sleep assessment․

Troubleshooting Common Issues

Device Not Powering On: First, verify the device is adequately charged using the provided power adapter․ Ensure the power cable is securely connected to both the device and a functioning power outlet; If the issue persists, attempt a different outlet or cable․ Contact technical support if charging fails․

Sensor Connectivity Problems: If the device displays an error related to sensor connectivity, gently re-connect the affected sensor (effort belt or SpO2 sensor)․ Confirm the sensor is properly inserted into the designated port on the Alice NightOne․

Check for any visible damage to the sensor cable․ If problems continue, consult the user manual or contact support for assistance․ Do not attempt to repair the sensors yourself․

Device Not Powering On

If your Alice NightOne device fails to power on, begin by confirming the charging process․ Connect the provided power adapter to the device and a known working electrical outlet․ Ensure the connection is secure at both ends – the device and the wall outlet․ Allow the device to charge for at least 30 minutes before attempting to power it on again․

If it still doesn’t turn on, try a different power outlet to rule out an outlet issue․ Inspect the power adapter and cable for any visible signs of damage, such as frayed wires or bent connectors․

If the problem persists, contact technical support immediately, referencing your device’s serial number for efficient assistance․ Do not attempt to disassemble or repair the device yourself․

Sensor Connectivity Problems

Experiencing issues with sensor connectivity during your Alice NightOne sleep study? First, ensure all sensors – the effort belt, SpO2 sensor, and nasal cannula – are firmly and correctly connected to the main device․ Check for any loose connections or dislodged cables․ Gently reseat each sensor to establish a secure link․

Verify that the sensors are properly positioned on your body, as detailed in the ‘Applying the Alice NightOne’ section of this manual․ Ensure the SpO2 sensor is clean and free from obstructions․ If the amber cannula indicator is flashing, re-secure the nasal cannula․

If problems continue, restart the device․ If issues persist, contact support, providing details about which sensor is failing to connect․

Safety Instructions and Precautions

Important Safety Information: Prior to using the Alice NightOne, carefully read and understand all safety guidelines outlined in this manual․ This device is intended for single-patient use only; do not share it with others․ Avoid getting the device or sensors wet, as this may cause malfunction or inaccurate readings․

Ensure the nasal cannula is securely fitted but not overly tight, preventing discomfort or skin irritation․ Do not attempt to disassemble or repair the Alice NightOne device yourself․ If you experience any adverse reactions, discontinue use immediately and consult your healthcare provider․

Keep the device away from extreme temperatures and direct sunlight․ Always follow your physician’s instructions regarding the sleep study and device operation․

General Safety Guidelines

User Responsibility: It is crucial to follow all provided instructions diligently for a safe and accurate sleep study with the Alice NightOne․ Ensure a comfortable, yet secure fit for all components – chest belt, nasal cannula, and SpO2 sensor – avoiding excessive tightness․

Do not modify the device or its accessories in any way․ If you experience skin irritation or discomfort, immediately adjust or discontinue use and contact your healthcare provider․ This device is designed for home use under medical supervision; self-diagnosis or treatment is not recommended․

Maintain a safe sleep environment, free from hazards․ Report any device malfunctions or unusual readings to your physician promptly․

Avoiding Device Damage

To ensure the longevity and accurate functioning of your Alice NightOne device, handle it with care․ Avoid exposing the device and sensors to excessive moisture, extreme temperatures, or direct sunlight․ Do not immerse the device in water or any other liquid․

Protect the device from physical shock, such as dropping or bumping․ Gently connect and disconnect sensors to prevent damage to the ports․ Store the Alice NightOne and its accessories in the provided case when not in use, safeguarding them from dust and potential harm․

Regularly inspect the components for any signs of wear and tear, and report any concerns to your healthcare provider․

Important Warnings

Caution: The Alice NightOne is a medical device intended for single-patient use only․ Do not share the device or its accessories with others․ If you experience any discomfort, skin irritation, or difficulty breathing while using the device, discontinue use immediately and consult your healthcare provider․

Do not attempt to disassemble, modify, or repair the Alice NightOne yourself․ This could compromise its functionality and void the warranty․ Keep the device out of reach of children and pets․ Ensure the nasal cannula is securely connected to prevent accidental dislodgement during sleep․

Always follow the provided instructions and safety guidelines to ensure a safe and accurate sleep study․